Construction/Cold Joints by Product |
MC-2010MN |
GENERAL USE - Cast-in-place non-moving joints. REQUIRMENT - Minimum of 4" of 4300+ psi concrete on both sides of the waterstop (minimum 9" wall /slab). Place in the center between two rows of rebar. Wall height must be a minimum of 6.5 feet. This product will withstand a high hydrostatic head. OVER 700 FOOT HEAD IN LABORATORY TESTS. Click on "installation instructions" for general installation information (pdf file). Click on "typical application " for photo examples. |
MC-2005M |
GENERAL USE: Cast-in-place joints with less than 50 foot hydrostatic head and less than 24" thick walls or slabs. Follow same installment criteria as MC-2010MN. Click on "Ideal Installation Instructions" for more info (pdf file). Check data sheet for detailed information. |
KBA-1510FP |
GENERAL USE - Cast-in-place non-moving joints (less than 20' hydrostatic head).
Can be placed outside of rebar to protect rebar from moisture. Requires a minimum of 1.0" of 4300+ psi concrete coverage. Because of unknow concrete conditions we recommend 1.5" ~ 2.0" if possible. Excellent for 6" ~ 8" walls/slabs with single row of rebar or pins. Click on "Data Sheet" to view more detailed information. |